Measurement Technique
Dualstream Venturi
Wet Gas Correction Algorithm
Liquid fraction from well test
Mechanical Specification
Standard Line Sizes 2” thro 24” Nominal bore
Pressure Class ANSI Class 300# to 2500# (API ratings on request)
Process Temperature Range -40 to 120°C
Meter Body Material Duplex UNS31803 as standard
Alternate pressure ratings (ANSI/API 15K), temperature rating, sizes and material available on request
Installation Requirements
Horizontal installation (vertical on request)
Upstream straight length: 3D to 10D typical (calibrated spool available for allocation systems)
Downstream straight length: None
(5D calibrated spool available with thermowell for allocation systems)
Compact flow meter design options are available for applications where installation envelope is restricted, please contact for details
Operating Range
Turndown: >8:1 typical
Gas Mass Fraction: 50-100%
Water Liquid Ratio: 0-100%
Typical Performance
Uncertainty (95% confidence level):
- Gas mass flow rate <5%
- Liquid mass flow rate from well test
Typical Repeatability
Gas Mass Flow Rate 0.15%
Instrumentation
Standard field instrumentation comprising:
- Differential pressure
- Gauge pressure
- Temperature
Data Acquisition
Options available include:
- Dualstream Flow Computer (safe area)
- Dualstream PC (safe area)
- Dualstream PC (hazardous area)
User Required Inputs
- Hydrocarbon Composition
- Compositional Data
- Liquid Density
- Liquid Fraction (from well test)
For full specification see datasheet