Skip to content

Temperature Transmitter SST3010 T

Solartron ISA - High performance instruments for the life of your reservoir.

Engineering Excellence for Long-term Performance
Operating subsea to ultra deepwater depths of 16,400 ft (5000 m) and high process pressures up to 10,000 psi (690 bar), the SST3010 T temperature transmitter has been developed to monitor well fluids in these most harsh environments.

Solartron ISA’s SST family sets the global performance standard for subsea measurement instrumentation in the oil and gas industry. Used by leading exploration companies, SST products have an unsurpassed service history in the field, even in the most demanding and hostile installation environments.

Highly Stable, Accurate Measurement
Solartron ISA has over 25 years of temperature measurement experience and can offer specialist design and measurement solutions to meet with customer requirements.

The SST3010 T is equipped with a 4-wire PT100 to IEC751 Class A RTD situated in an integral thermowell and terminating inside the main housing. The thermowell is positioned directly in the process stream which is the accepted industry standard for optimum accuracy and response time.

Key Specifications

  • Depth 16,400ft (5000m)
  • Pressure 10,000psi (690 bar)
  • Accurate to ±0.3% of span
  • Stability ±0.1% per 12 months
  • Optional Redundancy

Features
  • 4-20mA
  • Hart
  • CANopen (Fault Tolerant - SIIS Level 2)
  • CANopen (Hi-speed)
  • Modbus (RS485)


  • Specifications +


    Transmitter Output
    4-20 mA, HART, Modbus, CANopen (High-Speed),
    CANopen (Fault Tolerant - SIIS Level 2)

    Functional Specifications
    Ambient Temperature Limits
    -22 to 176°F (-30 to +80°C)
    Process Temperature Limits
    -40 to 302°F (-40 to 150°C)
    Working Pressure Limits
    Maximum working pressure limit 10,000 psi (690 bar)
    Maximum test pressure limit 15,000 psi (1035 bar)

    Installation
    Supply voltage
    10 to 40 VDC for analog operation
    16.4 to 32 VDC for digital communications

    Load
    0 to 1335Ω for analog operation
    250 to 600Ω for HART
    120Ω for Modbus
    1500 for CANopen