Measurement Technique
Enhanced Dual-Phase Version: Dualstream Venturi, Electromagnetic Resonant Cavity Employing Paired Sensor Combinations plus PVT Model
Typical Operating Range
Turndown >8:1
Gas Volume Fraction 90-100%
Water Liquid Ratio 0-100%
Typical Performance
Uncertainty (95% confidence level)
Gas Mass Flow Rate ±2%
Condensate Mass Flow Rate ±10%
Water Volume Fraction ±0.1% abs
Typical Repeatability
Gas Mass Flow Rate <0.40% Relative
Condensate Mass Flow Rate
<2.0%
Water Volume Fraction 0.02% abs
Permanent Pressure Loss
Pressure Loss Specific to Application <1bar
Instrumentation
Electromagnetic Resonant Cavity Sensors
Differential Pressure -
Class Leading True Digital Sensor
Gauge Pressure
Temperature - Non Intrusive Sensor
Installation Requirements
Horizontal or Vertical Orientation
Upstream Straight Length 3D Included in Meter Body
Downstream Straight Length (none required)
Data Acquisition
Max. Power Requirements 15W
Power Supply 24 V DC (16 V to 32 V)
Signal Output RS485 Modbus
Ethernet
User Required Outputs
Hydrocarbon Composition
Hazardous Area Approval
ATEX / IECEx / UKCA
II 2G Ex db eb IIB T6 Gb -20°C ≤ Ta ≤ 60°C
Additional Features
Salinity Detection