Skip to content
   

Dualstream 2

Smart solution for high liquid wet gas wells

Dualstream 2 is a 3-phase measurement solution for allocation or monitoring gas condensate wells. It is typically used on a per well basis at the wellhead or in the flow line on wells with high liquids.

Standard field instrumentation makes Dualstream 2 ideally suited for remote wellheads or unmanned platforms.

Common applications include tie-ins to existing infrastructure or new field development where real time high accuracy gas measurement is a fundamental operation requirement and water measurement accuracy is required for efficient well operation.

Dualstream 2 replaces the need for test separators or tracer dilution techniques.

New Plug and Play Compact Design
Our latest design benefits from Solartron ISA’s unrivalled experience developed over three decades in the engineering, installation and operation of wet gas flow meters. Recent enhancements have been implemented to reduce installation time, improve measurement performance and increase operational safety on wellheads and flow lines.

  • Real time 3-phase Data
  • GVF > 90%
  • Uncomplicated & Robust
  • Low OPEX
  • Industry Standard Computer
  • Large Installed base

Measurement Application
  • Royalty allocation
  • Hydrate Mitigation
  • Flow line monitoring

Principle of Operation
The basic principles used within Dualstream 2 are explained in the video below:



  • Specifications +


    Measurement Technique
    Dualstream Wet Gas Venturi
    PLR Measurement
    Dual DP Device
    Proprietary Wet Gas Algorithms

    Typical Operating Range
    Turndown >8:1 typical
    Gas Mass Fraction 50-100%
    Water Liquid Ratio 0-100%

    Typical Performance
    Typical Uncertainty (95% confidence level):
    Gas Mass Flow Rate ±2%
    Condensate Mass Flow Rate ±10%
    Water Volume Flow Rate ±1 am3/h

    Typical Repeatability
    Gas Mass Flow Rate <0.40% 
    Condensate Mass Flow Rate <2.0% 
    Water Sensitivity ±0.2 am3/h 
     
    Permanent Pressure Loss
    Pressure Loss Specific to Application <1 bar

    Instrumentation
    Standard Field Instrumentation Comprising:
    • Differential Pressure - class leading true digital sensor
    • Gauge Pressure - secondary variable from DP sensor
    • Temperature - non intrusive sensor

    Installation Requirements

    Horizontal Installation (vertical on request)
    Upstream Straight Length (none)
    Downstream Straight Length (none)

    Data Acquisition
    Dualstream Flow Computer Module – industrial 19” server (safe area)
    Options Available Include:
    • Industrial Flow Computer (safe area)
    • Dualstream Hazardous Area Flow Computer
    • Floor or Wall Mounted Panel (safe area)

    User Required Inputs
    • Hydrocarbon Composition

     

  • Downloads +

  • Guidelines +

  • Wet Gas Application Questionnaire +